Quote for DU-1-4 Part with NSN 5950-00-518-7522 by Signal Transformer Co Inc
Part No. : DU-1-4 | Alternate P/N : DU14 | Manufacturer : Signal Transformer Co Inc | Item Name : transformer power | CAGE Code : 08779 | NSN : 5950-00-518-7522 | FSC : 5950 coils and transformers |
Parts we carry include part number DU-1-4, Transformer Power with NSN 5950005187522 by Signal Transformer Co Inc. Just fill out the Request for Quote (RFQ) form below to get started on a quote. As you fill out the RFQ, make sure that all fields are properly completed. Your quote will be determined primarily by your response to asterisk-marked (*) fields like Need Parts By and Quantity (ea).
ASAP Distribution, is a leading distributor of Signal Transformer Co Inc obsolete and hard-to-find NSN parts like DU-1-4. We have a comprehensive inventory of more than 2 billion parts and industry-wide relationships with many MROs and manufacturers, allowing us to provide NSN parts and components for our customers in the aerospace, civil aviation, and defense industries.
One of our dedicated account representatives will get back to you in 15 minutes or less. If you would still like to expedite your quote for part DU-1-4, you can also call us at our toll-free number +1-714-705-4780, or email us at sales@asap-distribution.com.
NSN Information for Part Number DU-1-4 with NSN 5950-00-518-7522, 5950005187522
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-518-7522 Item Description: TRANSFORMER,POWER | 5950 | 005187522 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
DU-1/4 | 6 | 2 | 3 |
Characteristics Data of NSN 5950-00-518-7522, 5950005187522
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM5.312 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM5.250 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM4.250 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP0.196 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT500.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT0.250 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | OPENOPENOPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND SLOT SINGLE GROUPSLOT SINGLE GROUPSLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VO |
CWJS | WINDING OPERATING VOLTAGE | 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 104.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY OR 120.00 A |
TTQY | TERMINAL TYPE AND QUANTITY | 16 THREADED STUD |