Quote for JC2-B3CB-A-P1-15-3-P2-5-3 Part with NSN 5925-01-332-1035 by Eaton Corp
Part No. : JC2-B3CB-A-P1-15-3-P2-5-3 | Alternate P/N : JC2B3CBAP1153P253 | Manufacturer : Eaton Corp | Item Name : circuit breaker | CAGE Code : 74193 | NSN : 5925-01-332-1035 | FSC : 5925 circuit breakers |
Parts we carry include part number JC2-B3CB-A-P1-15-3-P2-5-3, Circuit Breaker with NSN 5925013321035 by Eaton Corp. Just fill out the Request for Quote (RFQ) form below to get started on a quote. As you fill out the RFQ, make sure that all fields are properly completed. Your quote will be determined primarily by your response to asterisk-marked (*) fields like Need Parts By and Quantity (ea).
ASAP Distribution, is a leading distributor of Eaton Corp obsolete and hard-to-find NSN parts like JC2-B3CB-A-P1-15-3-P2-5-3. We have a comprehensive inventory of more than 2 billion parts and industry-wide relationships with many MROs and manufacturers, allowing us to provide NSN parts and components for our customers in the aerospace, civil aviation, and defense industries.
One of our dedicated account representatives will get back to you in 15 minutes or less. If you would still like to expedite your quote for part JC2-B3CB-A-P1-15-3-P2-5-3, you can also call us at our toll-free number +1-714-705-4780, or email us at sales@asap-distribution.com.
NSN Information for Part Number JC2-B3CB-A-P1-15-3-P2-5-3 with NSN 5925-01-332-1035, 5925013321035
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-332-1035 Item Description: Circuit Breaker | 5925 | 013321035 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Jc2-B3cb-A-P1-15-3-P2-5-3 | 5 | 9 | 5 |
Characteristics Data of NSN 5925-01-332-1035, 5925013321035
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.606 INCHES MINIMUM AND 2.668 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.229 INCHES MINIMUM AND 2.291 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.629 INCHES MINIMUM AND 1.691 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES DC FIRST LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.900 MINIMUM AT 200 PCT ALL LOCATIONS AND 50.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG |
ADAT | BODY WIDTH | 1.119 INCHES MINIMUM AND 1.181 INCHES MAXIMUM |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.529 INCHES MINIMUM AND 1.591 INCHES MAXIMUM |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 65.0 DC SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
ADTV | CASE MATERIAL | PLASTIC |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |