NSN NSN Parts NSN 5950004219320

NSN 5950-00-421-9320, 5950004219320 Transformer Power Parts Sourcing

If you have been looking for Magnetika Inc, Bae Systems Information And Electronic Systems Integration Inc, New England Transformer Co Inc parts listed alongside the NSN 5950004219320, ASAP Distribution has you covered with our unmatched inventory of items Transformer Power. With over 2 billion parts readily available for purchase on our website, customers can get competitive pricing offers and rapid lead-times on top NSN part numbers such as TW-7693, 243156P1, NE 9205. Explore our NSN parts catalog at your leisure, or you may take advantage of our provided search engine to find specific parts in a matter of moments. If you are interested in this particular component or others listed across our website, you may begin the procurement process at any time through the submission of an Instant RFQ form. Using the information that you submit to us, our team of industry experts will quickly craft you a quote that accommodates your individual needs and requirements for NSN 5950004219320.

Alternative NSN: 5950-00-421-9320 Item Name : Transformer Power FSG : 59 Electrical and Electronic Equipment Components Federal Supply Class (FSC) : 5950 Coils and Transformers NIIN: 004219320 NCB Code: USA (00)

Part Number's List for NSN 5950-00-421-9320, 5950004219320

Part No Manufacturer Item Name QTY RFQ
TW-7693 Magnetika Inc transformer power Avl RFQ
243156P1 Bae Systems Information And Electronic Systems Integration Inc transformer power Avl RFQ
NE 9205 New England Transformer Co Inc transformer power Avl RFQ

Characteristics Data of NSN 5950004219320

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABHPOVERALL LENGTH2.660 INCHES MAXIMUM
ABKWOVERALL HEIGHT3.500 INCHES MAXIMUM
ABMKOVERALL WIDTH1.800 INCHES MAXIMUM
ACZBFREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZCINPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
ACZXWINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
AKNAINCLOSURE TYPEFULLY INCLOSED
AXGYMOUNTING METHODTERMINAL SINGLE GROUP
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
CRBZWINDING OPERATING CURRENT15.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
CRBZWINDING OPERATING CURRENT55.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
CRBZWINDING OPERATING CURRENT55.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE195.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
CWJSWINDING OPERATING VOLTAGE3.60 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
CWJSWINDING OPERATING VOLTAGE370.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
CWJSWINDING OPERATING VOLTAGE5.88 AC KILOVOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
TTQYTERMINAL TYPE AND QUANTITY13 WIRE LEAD
INSTANT RFQ