NSN 5905-00-061-3214, 5905000613214 Resistor Fixed Wire Wound Induct Parts Sourcing
If you have been looking for Tektronix Inc, Tepro Of Florida Inc, Shallcross Inc, Esystems Inc, Avox Systems Inc parts listed alongside the NSN 5905000613214, ASAP Distribution has you covered with our unmatched inventory of items Resistor Fixed Wire Wound Induct. With over 2 billion parts readily available for purchase on our website, customers can get competitive pricing offers and rapid lead-times on top NSN part numbers such as 308-0262-00, TS5W153F, LA446-15 K OHM +-5 P, VL-0005-15 K OHM 5 P, SA50 15 KOHM 5 PERC. Explore our NSN parts catalog at your leisure, or you may take advantage of our provided search engine to find specific parts in a matter of moments. If you are interested in this particular component or others listed across our website, you may begin the procurement process at any time through the submission of an Instant RFQ form. Using the information that you submit to us, our team of industry experts will quickly craft you a quote that accommodates your individual needs and requirements for NSN 5905000613214.
Alternative NSN: 5905-00-061-3214 | Item Name : Resistor Fixed Wire Wound Induct | FSG : 59 Electrical and Electronic Equipment Components | Federal Supply Class (FSC) : 5905 Resistors | NIIN: 000613214 | NCB Code: USA (00) |
Part Number's List for NSN 5905-00-061-3214, 5905000613214
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
308-0262-00 | Tektronix Inc | resistor fixed wire wound induct | Avl | RFQ |
TS5W153F | Tepro Of Florida Inc | resistor fixed wire wound induct | Avl | RFQ |
LA446-15 K OHM +-5 P | Shallcross Inc | resistor fixed wire wound induct | Avl | RFQ |
VL-0005-15 K OHM 5 P | Esystems Inc | resistor fixed wire wound induct | Avl | RFQ |
SA50 15 KOHM 5 PERC | Avox Systems Inc | resistor fixed wire wound induct | Avl | RFQ |
RS5-15KP0RM5PCT | Vishay Dale Electronics Inc | resistor fixed wire wound induct | Avl | RFQ |
RS515K5WP0RM5PCT | Vishay Dale Electronics Inc | resistor fixed wire wound induct | Avl | RFQ |
P21C9972-27 | Sundstrand International Corporation | resistor fixed wire wound induct | Avl | RFQ |
747045-67 | L 3 Communications Cincinnati | resistor fixed wire wound induct | Avl | RFQ |
RS5-70-1502F | Vishay Dale Electronics Inc | resistor fixed wire wound induct | Avl | RFQ |
P21C9972-27 | Hamilton Sundstrand Corporation | resistor fixed wire wound induct | Avl | RFQ |
280-1138P67 | Raytheon Company | resistor fixed wire wound induct | Avl | RFQ |
P500-1502F | Mepco Electra Inc | resistor fixed wire wound induct | Avl | RFQ |
308-108 | Tektronix Inc | resistor fixed wire wound induct | Avl | RFQ |
141110143 | Eaton Corp | resistor fixed wire wound induct | Avl | RFQ |
352250024978 | Thales Nederland B V | resistor fixed wire wound induct | Avl | RFQ |
5KTCBRACKET14000OHMS | Sprague Electric Co | resistor fixed wire wound induct | Avl | RFQ |
CW-5 15K OHMS 5 | Vishay Dale Electronics Inc | resistor fixed wire wound induct | Avl | RFQ |
CS7 15 K OHM 5 PERCE | Ultronix Inc | resistor fixed wire wound induct | Avl | RFQ |
1550S 15 K OHM 5 PER | Struthers Dunn Llc | resistor fixed wire wound induct | Avl | RFQ |
HL605Z8-15001J | Vishay Dale Electronics Inc | resistor fixed wire wound induct | Avl | RFQ |
5X15000WL | Ward Leonard Electric Company Inc | resistor fixed wire wound induct | Avl | RFQ |
RS-5U000N15001F | Vishay Dale Electronics Inc | resistor fixed wire wound induct | Avl | RFQ |
225S15K00J | Heico Ohmite Llc | resistor fixed wire wound induct | Avl | RFQ |
CW5-15001J | Vishay Dale Electronics Inc | resistor fixed wire wound induct | Avl | RFQ |
Characteristics Data of NSN 5905000613214
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -30.0 TO 30.0 |
AAPP | III ELECTRICAL RESISTANCE | 15.000 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABPM | BODY DIAMETER | 0.281 INCHES MINIMUM AND 0.343 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.813 INCHES MINIMUM AND 0.937 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 5.000 FREE AIR |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-26 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-26/5 GOVERNMENT SPECIFICATION |
Search other Related NSN or NATO Stock Number for 5905-00-061-3214, 5905000613214