Quote for 2780 Part with NSN 5950-00-648-6127 by Transformer Technicians Inc
Part No. : 2780 | Manufacturer : Transformer Technicians Inc | Item Name : transformer power | CAGE Code : 96253 | NSN : 5950-00-648-6127 | FSC : 5950 coils and transformers |
Parts we carry include part number 2780, Transformer Power with NSN 5950006486127 by Transformer Technicians Inc. Just fill out the Request for Quote (RFQ) form below to get started on a quote. As you fill out the RFQ, make sure that all fields are properly completed. Your quote will be determined primarily by your response to asterisk-marked (*) fields like Need Parts By and Quantity (ea).
ASAP Distribution, is a leading distributor of Transformer Technicians Inc obsolete and hard-to-find NSN parts like 2780. We have a comprehensive inventory of more than 2 billion parts and industry-wide relationships with many MROs and manufacturers, allowing us to provide NSN parts and components for our customers in the aerospace, civil aviation, and defense industries.
One of our dedicated account representatives will get back to you in 15 minutes or less. If you would still like to expedite your quote for part 2780, you can also call us at our toll-free number +1-714-705-4780, or email us at sales@asap-distribution.com.
NSN Information for Part Number 2780 with NSN 5950-00-648-6127, 5950006486127
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-648-6127 Item Description: Transformer Power | 5950 | 006486127 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2780 | 6 | 9 | 3 |
Characteristics Data of NSN 5950-00-648-6127, 5950006486127
MRC | Criteria | Characteristic |
---|---|---|
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.812 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.297 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.844 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 410.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 8 STANDOFF INSULATOR" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.812 INCHES NOMINAL" |
ADAT | BODY WIDTH | 2.297 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.844 INCHES NOMINAL" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 3.2 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 410.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 8 STANDOFF INSULATOR" |
Related NSN Part Number To 2780
Part 2780 With Different Manufacturers
2780
2780