NSN NSN Parts NSN 5925001330451

NSN 5925-00-133-0451, 5925001330451 Circuitbreaker Parts Sourcing

If you have been looking for Sae International, Embraer S A, Eaton Corp, Society Of Automotive Engineers Inc parts listed alongside the NSN 5925001330451, ASAP Distribution has you covered with our unmatched inventory of items Circuitbreaker. With over 2 billion parts readily available for purchase on our website, customers can get competitive pricing offers and rapid lead-times on top NSN part numbers such as SAE-AS58091, 6401692, MS25361-100, MP160-012-100, AS25361. Explore our NSN parts catalog at your leisure, or you may take advantage of our provided search engine to find specific parts in a matter of moments. If you are interested in this particular component or others listed across our website, you may begin the procurement process at any time through the submission of an Instant RFQ form. Using the information that you submit to us, our team of industry experts will quickly craft you a quote that accommodates your individual needs and requirements for NSN 5925001330451.

Alternative NSN: 5925-00-133-0451 Item Name : Circuitbreaker FSG : 59 Electrical and Electronic Equipment Components Federal Supply Class (FSC) : 5925 Circuit Breakers NIIN: 001330451 NCB Code: USA (00)

Part Number's List for NSN 5925-00-133-0451, 5925001330451


Characteristics Data of NSN 5925001330451

MRCCriteriaCharacteristic
AAQLBODY STYLESINGLE POLE TYPE
ABXDBUSHING LENGTH0 250 INCHES NOMINAL
ADAQBODY LENGTH2 189 INCHES MAXIMUM
ADATBODY WIDTH0 750 INCHES MAXIMUM
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1 438 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1 812 INCHES NOMINAL
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2 250 INCHES NOMINAL
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE100 0 AMPERES AC AND 100 0 AMPERES DC SINGLE LOCATION
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS115 0 AC AND 28 0 DC SINGLE LOCATION
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS3500 0 AC AND 6000 0 DC SINGLE LOCATION
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT SINGLE LOCATION
CPRJTRIP RELEASE METHODTHERMAL SINGLE LOCATION
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY SINGLE LOCATION
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138 0 SINGLE LOCATION
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 PUSH-PULL
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP SINGLE LOCATION
CQJXNOMINAL THREAD SIZE0 138 INCHES
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT15 000 MINIMUM AT 200 PCT AND 65 000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND EXPLOSION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATING25 0 DEG CELSIUS NOMINAL SINGLE LOCATION
FREQFREQUENCY IN HERTZ400 0 SINGLE LOCATION
TESTTEST DATA DOCUMENT81349-MIL-C-5809 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS BROCHURESETC THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS INDUSTRY DIRECTORIES AND SIMILAR TRADE PUBLICATIONS REFLECTIN
THSDTHREAD SERIES DESIGNATORUNC
TTQYTERMINAL TYPE AND QUANTITY2 SCREW
ZZZKSPECIFICATIONSTANDARD DATA96906-MS25361 GOVERNMENT STANDARD
INSTANT RFQ